HiBAR Spray-Applied Fire-Resistive
Material (SFRM)
HiBARTM is a ULC listed,
spray applied semi cementitious mineral fibre insulation, for fire
rating structural steel. HiBARTM also has thermal and
acoustical properties. It can be spray applied over rigid
structural substrates and exterior or partition walls. It provides
acoustical treatment for ceilings and walls in noisy production
areas or large rooms such as gymnasiums or swimming pools where
both sound absorption and aesthetic enhancement is desired.
Condensation control is also provided on exposed structural
components that are in contact with cold exterior surfaces.
|
Basic Uses
Spray-applied fireproofing for use over
rigid structural substrates such as
open web steel joists, beams, columns,
floor/ceiling assemblies and exterior or
partition wall units.
Thermal insulation for prefabricated
metal buildings, corrugated metal
roof assemblies, underside of
concrete slabs and masonry or
metal wall assemblies.
Spray-applied acoustical treatment
for ceilings and upper walls in noisy
production areas or in large rooms
such as gymnasiums or swimming
pools where both sound absorption
and aesthetic enhancement is desired.
Spray-applied treatment to provide
condensation control on exposed
structural components that are in
contact with cold exterior surfaces.
|
![]() ![]() |
Limitations
- HiBARTM is not suitable for exterior surfaces that might be exposed to moisture infiltration or to interior areas subjected to high humidity unless adequate ventilation is provided.
- Maximum thickness on rigid overhead areas without mechanical support is 75 mm. Thickness of over 38 mm generally require treatment with primary adhesive.
- Wood surfaces or substrates covered with high-gloss or water emulsion paints may require treatment with primary adhesive.
- Substrates covered with dirt, loose scale, oil, peeling paint or other substances that would impair bonding must be cleaned or sand blasted, and checked for acceptable bonding properties before application of HiBAR. Consult with a HiBAR representative.
Basic Uses
- Spray-applied fireproofing for use over rigid structural substrates such as open web steel joists, beams, columns, floor/ceiling assemblies and exterior or partition wall units.
- Thermal insulation for prefabricated metal buildings, corrugated metal roof assemblies, underside of concrete slabs and masonry or metal wall assemblies.
- Spray-applied acoustical treatment for ceilings and upper walls in noisy production areas or in large rooms such as gymnasiums or swimming pools where both sound absorption and aesthetic enhancement is desired.
- Spray-applied treatment to provide condensation control on exposed structural components that are in contact with cold exterior surfaces.
Limitations
- HiBARTM is not suitable for exterior surfaces that might be exposed to moisture infiltration or to interior areas subjected to high humidity unless adequate ventilation is provided.
- Maximum thickness on rigid overhead areas without mechanical support is 75 mm. Thickness of over 38 mm generally require treatment with primary adhesive.
- Wood surfaces or substrates covered with high-gloss or water emulsion paints may require treatment with primary adhesive.
- Substrates covered with dirt, loose scale, oil, peeling paint or other substances that would impair bonding must be cleaned or sand blasted, and checked for acceptable bonding properties before application of HiBAR. Consult with a HiBAR representative.
Composition
HiBARTM is a blend of
specially manufactured inorganic mineral fibres and proprietary
binders. The composite contains no asbestos or free crystalline
silica.
Technical Data
The following data reflect established
HiBAR performance criteria - consult with the manufacturer for
updated test information.
| Fire Rating (ULCS102/ASTM E-84) | |
| - Flame Spread | 0 |
| - Fuel Contributed | 0 |
| - Smoke Developed | 0 |
| Thermal Resistance (ASTM C518-76) | RSI 0.66 / 25mm (R3.76 / inch) |
| Thermal Conductivity (ASTM C518-76) | KSI 0.383 (K 0.266) |
| Combustibility (CAN4-S114) | Noncombustible |
| Marine Structural Fire Insulation | Coast Guard A-60 Rating |
| Air Erosion (ASTM E859-82) | Less than 0. 144 mg/m2 |
| Sound Absorption (ASTM C423), solid backing sprayed with 1 1/2" HiBAR (frequency/absorption) |
125/.42, 250/.60, 500/.94, 1000/1.08,
2000/1.03, 4000/1.03, NRC/.92 |
| Light Reflectivity | Approximately 80% |
| Fire Resistance (ULC S101/ASTM E119) | |
| - Wall ULC design No. W803 | (1 & 2 hr) |
| - Column ULC design No. Z804 | (1, 2, & 3 hr) |
| - Floor/Ceiling ULC design No. F820 | (1 & 2 hr) |
| - Roof ULC design No. R807 | (1 hr) |
| Thermal Barrier (ULC S124) (rating/thickness) | 10 minutes/22 mm, 15 minutes/32mm |
| Corrosivity | None |
| Bond Strength (ASTM E736-80) | Exceeds 20 times material dry weight |
Maintenance
HiBARTM requires no general
maintenance. Building owner should periodically inspect fireproofed
areas to ensure no material has been dislodged or damaged.

- Save money on your monthly bills
- Have a more comfortable house
- Make sure your house is properly vented (so you
don’t get mould)
- Get rid of drafty areas in your house
- Sound proof your home with foam
- We do all types of insulation to make sure you
get the right one
- We make sure you get the maximum out of your
grants
- Locally owned and operated